
APUS 95,000 BTU Natural Gas Indoor
6.8Good · out of 10$299.99 Price on Sep 30, 2026 · may have changed- Stated: 4.42 GPM · 95,000 BTU/h · 120 V
- 141 buyer reviews
- Gas tankless water heaters

Product images: Amazon listings
Written from the listing and 141 buyer reviews, not from our own use · How we rate
A 4.42 GPM maximum flow, a 0.81 UEF rating and a ±1 °F temperature hold: the APUS 95,000 BTU Natural Gas Indoor covers what matters most in an indoor gas tankless heater. It suits a cabin, a garage apartment or an in-law suite, at 6.8/10 on our rating.
These 141 buyer reviews (4.4/5) are shared by the 95,000 BTU Natural Gas Indoor and 80,000 BTU Natural Gas Indoor listings, so they speak for the family more than for one size.
| Brand | APUS |
|---|---|
| Category | Gas tankless water heaters |
| Fuel | Natural gas |
| Stated mounting location | Indoor |
| Stated maximum flow | 4.42 GPM |
| Stated gas input | 95,000 BTU/h |
| Stated voltage | 120 V |
| Stated efficiency | 0.81 UEF |
| Temperature range | 95 to 140 °F |
| Temperature hold | ±1 °F, per the listing |
| Freeze protection | Stated in the listing |
| Buyer reviews | 141 · 4.4/5, shared by the APUS listing family (2 variants) |
| ASIN | B0FF4FXDPJ |
Full listing title: APUS Natural Gas Tankless Water Heater, 95,000 BTU, 4.42 GPM Indoor
| Fuel | Natural GasFull listing title |
|---|---|
| Stated mounting location | IndoorFull listing title |
| Stated maximum flow | 4.42 GPMFull listing title |
| Stated gas input | 95,000 BTUFull listing title |
| Stated voltage | 120VListing text |
Two gas tankless heaters on natural gas too, with about the same flow, closest to it on our rating, each with a dated price.



That's the maximum flow the listing states, and headline flows are usually quoted at a mild temperature rise. With January water coming in at 42 °F and a 105 °F shower, the rise is 63 °F and the real flow is lower; the maker's flow chart has that number. At 2 GPM a shower (our calculator's figure), the headline means one shower at a time.
What it has going for it
0.81 UEF. Uniform Energy Factor is the federal efficiency label: the higher it is, the less gas or power goes up the vent instead of into your shower.
±1 °F hold. The burner adjusts as the flow changes, so the shower stays where you set it when somebody opens the kitchen tap. On paper, at least: that is the seller's claim.
One at a time: that's what 4.42 GPM is for. The seller says it serves up to 2 showers.
Two at once: not with this one. Look at the bigger units further down this page.
The seller states, word for word, in the APUS 95,000 BTU Natural Gas Indoor listing:
As a versatile natural gas tankless water heater, it meets simultaneous hot water demands for 2 showers plus 1 sink while maintaining stable temperatures even during peak usage.
With high-precision sensors and smart CPU technology, this tankless water heater maintains water temperature within ±1°F of your desired setting (adjustable from 95°F-140°F).
Our reliable natural gas water heater includes multiple-layer safety protection and a 2-year coverage.
That's the seller talking, not us. No listing tells you how it copes with 42 °F water at 6:45 in the morning.

What the APUS 95,000 BTU Natural Gas Indoor listing names:
For the APUS 95,000 BTU Natural Gas Indoor, the installation manual settles the venting, the gas line and the clearances.

At the price on Sep 30, 2026, each GPM of stated maximum flow works out at about $67.87 (price ÷ stated GPM, our arithmetic). That puts it in the cheaper third of the 45 indoor gas tankless heaters we have a price and a stated flow for.
The heater is often the smaller half of the bill: the venting, a gas line that may need upsizing and a licensed installer's day come on top.
The button opens the exact listing (ASIN B0FF4FXDPJ), where today's price, stock and seller apply. Sizes and variants of the same family often sit at different prices.

Two showers and the dishwasher at once? The Ranein 190,000 BTU Natural Gas Indoor (7.9/10) states up to 8.5 GPM.
No easy route for a vent pipe? The LiberLive 130,000 BTU NG Outdoor, Gray (7.3/10) mounts on an outside wall, per its listing.
Want the high-efficiency kind? The ThermoMate Condensing Natural Gas (7.7/10) is a condensing unit rated 0.86 UEF, per its listing.
Our take
Our favourite thing about the APUS 95,000 BTU Natural Gas Indoor is a 4.42 GPM maximum flow, closely followed by a 0.81 UEF rating. 141 buyers give it 4.4/5, which is a solid sign. The catch with this APUS indoor gas tankless heater: no word on the warranty. We'd pick it if a shower that suddenly runs cold drives you mad; otherwise, put it next to the Eccotemp i12-LP Propane Indoor first.
Old tank out, unit on the wall, vent through the wall or the roof. Plan the gas line for 95,000 BTU/h; a licensed pro handles it, and often a permit.
Hot water arrives after the cold already in the pipes, then stays (within ±1 °F, per the listing). A trickle from a bathroom tap may not light the burner; open it a bit more.
January water comes in colder, so the same unit gives fewer GPM. Stagger the showers if you sized it tight.
Flush the heat exchanger with a pump and a descaler (the service valves make it an hour's job), and clean the inlet filter. Our flushing and descaling guide has the checklist.
Buyers give it 4.4/5, a strong record, above our ranked picks' 4.3 average. 141 reviews is a fair sample, enough for the average to mean something. The same reviews appear on both variants of the APUS family, so they describe the family rather than this exact variant.
Before you order the APUS 95,000 BTU Natural Gas Indoor, check your gas line: 95,000 BTU/h is a lot of gas at once, so ask your plumber whether the existing line can feed it.
4.42 GPM is the headline. In a northern January the water comes in near 42 °F, so a 105 °F shower needs a 63 °F rise and the real flow drops. Our flow-rate calculator runs the numbers for your house.
Ask the plumber to check the gas line size and the meter against the heater's input, and to quote the vent route at the same visit. Our install cost guide shows what that usually adds.
Read what it requires: a licensed install, the gas type and regular flushing are the usual conditions.
Hard water scales the heat exchanger. Service valves on the water lines turn the yearly flush into an hour with a bucket and a pump; our flushing and descaling guide shows the routine.
How the APUS 95,000 BTU Natural Gas Indoor stacks up against the closest alternative, the Eccotemp i12-LP Propane Indoor.
| Criterion | APUS 95,000 BTU Natural Gas Indoor | Eccotemp i12-LP Propane Indoor |
|---|---|---|
| Our rating | 6.8/10 | 6.9/10 |
| Max flow | 4.42 GPM | Not stated |
| Gas input | 95,000 BTU/h | Not stated |
| Efficiency | 0.81 UEF | Not stated |
| Temperature hold | ±1 °F stated | Not stated |
| Buyer reviews | 141 · 4.4/5 | None captured |
Pick the Eccotemp i12-LP Propane Indoor if you want our higher-rated option (6.9/10); stay with the APUS 95,000 BTU Natural Gas Indoor for more flow (4.42 GPM) and a bigger burner (95,000 BTU/h).
We rate it 6.8/10 (good). It is based on 141 buyer reviews averaging 4.4/5, shared by the APUS listing family (2 variants) and the specifications stated in the listing.
The listing states a maximum flow of 4.42 GPM and a gas input of 95,000 BTU/h on 120 V. The headline flow is a mild-weather number: with cold winter water coming in, the same unit gives you less. Read the maker's flow chart at your winter rise, or let our flow-rate calculator do the sums.
Yes, the listing says indoor mounting. That means a vent route to the outside, combustion air and a gas line sized for the unit, all as the maker and your local code require. A licensed plumber or gas fitter sorts that out.
No. The same review pool appears on every variant of the APUS listing family: 141 reviews averaging 4.4/5 on the APUS 95,000 BTU Natural Gas Indoor and APUS 80,000 BTU Natural Gas Indoor. The count therefore describes the family, not this exact variant, and in our rankings the family takes a single slot.
Its listing states up to 4.42 GPM, a 0.81 UEF rating, temperature held within ±1 °F and freeze protection. These are the seller's figures, not our measurements: how steady the temperature is in your shower and how it copes with your winter water can't be read from a listing.
Your winter flow: 4.42 GPM is the headline. In a northern January the water comes in near 42 °F, so a 105 °F shower needs a 63 °F rise and the real flow drops. Our flow-rate calculator runs the numbers for your house. Vent and gas line: ask the plumber to check the gas line size and the meter against the heater's input, and to quote the vent route at the same visit. Our install cost guide shows what that usually adds. The warranty terms: read what it requires: a licensed install, the gas type and regular flushing are the usual conditions. Flushing: hard water scales the heat exchanger. Service valves on the water lines turn the yearly flush into an hour with a bucket and a pump; our flushing and descaling guide shows the routine.
We link to the exact listing on Amazon, where today's price, stock and seller apply. It is an affiliate link, and it has no effect on the rating.
No, we haven't used it ourselves. Everything on this page comes from its listing and 141 buyer reviews, read line by line and weighed with our published formula.